EXPERIMENTAL STUDIES ON THE SURFACE ROUGHNESS OF GLASS IONOMER CEMENT RESTORATIONS

Glass Ionomer Cement 수복물(修復物)의 표면거칠기에 관한 실험적 연구

  • Kim, Kwang-Soon (Department of Conservative Dentistry, College of Dentistry, Yonsei University) ;
  • Lee, Seung-Jong (Department of Conservative Dentistry, College of Dentistry, Yonsei University) ;
  • Lee, Chung-Suck (Department of Conservative Dentistry, College of Dentistry, Yonsei University)
  • 김광순 (연세대학교 치과대학 보존학교실) ;
  • 이승종 (연세대학교 치과대학 보존학교실) ;
  • 이정석 (연세대학교 치과대학 보존학교실)
  • Published : 1992.03.31

Abstract

One disadvantage of Glass Ionomer Cement Restoration is the difficulty in polishing. To find the appropriate polishing method, we polished the surface of Glass Ionomer Cement Restorations by 11 combination methods serially using disks shared with large-small particles and evaluated the polishing process in terms of surface roughness, surface roughness curve, and SEM findings. In addition, a visible light curing type bonding material was applied to evaluate the possible improvement in surface properties. The following results were obtained. 1. The disk surface of Glass Ionomer Cement was polished serially by disks with superfine particles, but it didn't become smooth. 2. The surface of Microfilled Composite resin became smoother as using a disk with finer particles. 3. When a visible light curing type bonding material was applied in finishing process, the surface of Glass Ionomer Cement became smooth as much as the applied matrix.

Keywords