Experimental Study on the Cooling seasonal Performance Factor of Room Air-conditioner

에어컨의 냉방기간 에너지 효율 산출을 위한 실험적 연구

  • 이홍원 (삼성전자 가전종합연구소 냉동공조연구실) ;
  • 문정호 (삼성전자 가전종합연구소 냉동공조연구실) ;
  • 배영돈 (삼성전자 가전종합연구소 냉동공조연구실) ;
  • 박종철 (삼성전자 가전종합연구소 냉동공조연구실)
  • Published : 1992.08.01

Abstract

In most cases, EER(Energy Efficiency Ratio) is available to present energy efficiency of air-conditioners. But, EER is not adapt to measure energy efficiency at actual life environment because it is based on fixed temperature and humidity contditions. To overcome this disadvantage, there is need to introduce SEER(Seasonal Energy Efficiency Ratio) established at time varient temperature and humidity conditions. In this paper, SEER measurement method and conditions based on actual life environment of the country is introduced, and discussed SEER value about two air-conditioner type, that is, non inverter air-conditioner and inverter air-conditioner. As a result of, inverter air-conditioner was superior to non inverter air-conditioner at cooling seasonal energy efficiency.

Keywords