An experimental study of the rotating heat pipe with a dished evaporator

접시형 증발부를 가진 회전형 히이트파이프의 실험적 연구

  • Kwon, Sun-Sok (Department of Mechanical Engineering, Dong-A Univ.) ;
  • Jang, Young-Suc (Department of Mechanical Engineering, Kyung-Nam Junior College) ;
  • Yoo, Byung-Wook (Department of Mechanical Engineering, Dong-A Univ.)
  • 권순석 (동아대학교 기계공학과) ;
  • 장영석 (경남전문대학 기계공학과) ;
  • 유병욱 (동아대 대학원 기계공학과)
  • Published : 1992.12.30

Abstract

By using the heat pipe with a dished evaporator and a screwed groove condenser, the heat transfer characteristics have been investigated by measuring temperature distributions of wall and vapor for various thermal inputs at rotative and stationary cases. The results show that the heat transfer characteristics of this pipe have better than those of simple heat pipe. The heat transfer of the heat pipe is increased by increasing thermal input and revolutions per minute.

증발부를 접시형으로 하고 응축부를 나선형 그루우브로 하는 히이트파이프에서 움직이지 않는 경우와 회전을 하는 경우 입 열량에 따라 벽면과 증기의 온도분포를 구하여 전열특성을 연구하였다. 본 연구에 사용된 히이트파이프는 단순 히이트파이프보다 우수한 전열특성을 가지며, 히이트파이프의 열전달은 입열량과 회전수가 증가하면 증가하였다.