Acknowledgement
Supported by : 한국학술진흥재단
This study was conducted to develop an electro-hydraulic three-point hitch control system using an electro-hydraulic servo valve and microcomputer and to investigate the performance of the three-point hitch control system through indoor and field experiments. 1. The results from indoor experiments coincided with those from computer simulation reported in the previous paper. However, the draft control with the value 4 of Kd showed a slight sustained oscillation after it reached the draft set. 2. From the field experiments, it appeared that the RMS errors increased with the ground speed of tractor. In position control, the three-point hitch control system with electro-hydraulic servo valve showed better performance than that with on-off electro-magnetic valve in the ground speed less than 1.6 m/s. In draft control, however, there was no significant differece in performance between those two systems. 3. In depth control, the both types of electro-hydraulic three-point hitch control system showed better performance than the conventional mechanical-hydraulic three-point hitch control system.
Supported by : 한국학술진흥재단