Abstract

In close-range photogrammetry, to employ non-metric camera especially for the purpose of precise measurement, systematic errors must, first of all, be corrected as they have a great influence on accuracies of results. For it, fiducial marks was built in non-metric camera and the factors such as PPS, PPA, EFL, CFL, and radial lens distortion coefficients for each quadrant were calibrated through collimator test. Also, the coefficients of both radial and tangential lens distortion were calibrated from analytical plumb line method and therefore main systematic errors could be effectively corrected. Using the calibrated non-metric camera, close-range photogrammetry could be successfully accomplished and accuracies could be improved sharply.

근거리 사진측량에서 정오차의 보정은 정확도 향상에 중요한 영향을 미치며, 특히 비측량용사진기를 정밀측량에 이용하기 위해서는 정오차에 대한 보정이 선행되어야 한다. 이를 위해 비측량용사진기에 지표를 설치하고 collimator검정방법에 의해 렌즈의 PPS, PPA, EFL, CFL 및 각 상한별 렌즈의 방사방향 왜곡계수를 구하였고, plumb line 검정방법에 의해서도 렌즈의 방사방향 및 접선방향에 대한 왜곡계수를 구하여 정오차 보정을 효율적으로 시도하였다. 이 검정된 비측량용사진기를 이용하여 근접사진측량을 실시하고, 정오차를 보정하므로써 정확도 향상을 꾀할 수 있었다.