The Investigation on the Behavior of Beam-Column Joint with High and Low Strength Concerte
고강도와 보통강도 콘크리트를 사용한 보-기둥 접합부의 구조적 거동
Abstract
AC] 318-H9 Recommended that when the specified compressive strength of concrete in a column is greater than 1. 4 times that specified for a floor system, top surface of the colurrm concrete shall extend 2ftU;OOrrun) into the slab from the face of colUlml to avoid unexpected brittle failure. The purpose of this investigation is to suggest the basic information for the structural safety, The major variables are com preSSlve strength of concrete, shear confinement ratio, and loading types. The test results showed that the load capaCIty of speCImen subjected to monotOI1lC loading had more than that of specimen subjected to one way cyclic loading. The failure modes of specimens under cyclic loading were concentrated at 5-20cm apart region from beam-column joint face and ductility index are increased with increasing of shear confinement ratio. Keywords: ACI 318-89, High and Low Strength Concrete, Beam-Column Joint, Shear Confinement Ratio, Loading Type, Ductility Index, Extension Distance.
R/C라멘골조에 있어서 수직부재(기둥, 벽등)에 수평부재(보, 슬라브등)의 콘크리트 강도보다 1.4배가 넘는 강도의 콘크리트를 분리타설할 경우 ACI 318-89 R10. 13. 1은 수직부재에 타설한 콘크리트가 수평부재로 2ft(60cm)이상의 내민길으를 확보하도록 규정하고 있다. 이에 따라 본 연구는 이 규정을 그대로 적용하기에 앞서 실험적인 검증을 통하여 구조적인 안전성을 확보하기 위하여 주요변수로서 콘크리트 압축강도, 전단보강비, 하중재하방법 등을 두어 총 6개의 시험체를 시험 및 분석하였다. 실험결과는 일방향 단조하중을 받는 시험체가 반복하중을 받는 시험체보다 다소 낮은 하중 수행능력을 보였다. 반복하중을 받는 시험체의 경우 접합면으로부터 5~20cm정도 떨어진 부분에 집중적인 균열이 발생하였으나 2ft(60cm)의 내민길이 면에서의 거의 균열이 발생하지 않아 현재 ACI의 내민길이 2ft(60cm)에 대한 규정은 매우 안전한 것으로 사료되며, 전단보강비가 증가함에 따라 부재의 연성능력이 증가하는 것으로 나타나 요구되는 전단보강근양의 50%이하는 부재의 거동에 다소 불리하나 50%를 초과하는 전단보강은 과다한 보강인 것으로 나타났다.