The Journal of Korean Academy of Prosthodontics (대한치과보철학회지)
- Volume 29 Issue 1
- /
- Pages.281-287
- /
- 1991
- /
- 0301-2875(pISSN)
- /
- 2005-3789(eISSN)
INFLUENCE OF THE CLASP ARM LENGTH ON THE CHANGE OF RETENTIVE FORCE WITH REPEATED PLACEMENT AND REMOVAL
반복 장착 철거시 CLASP ARM의 길이가 유지력의 변화에 미치는 영향
- Ahn, Kwang-Ho (Department of Prosthodontics, College of Dentistry, Wonkwang University) ;
- Dong, Jin-Keun (Department of Prosthodontics, College of Dentistry, Wonkwang University) ;
- Jin, Tai-Ho (Department of Prosthodontics, College of Dentistry, Wonkwang University)
- Published : 1991.01.01
Abstract
This study was designed to investigate the influence of the clasp arm length on the change of retentive force with repeated placement or removal. The author measured the retentive force of Akers clasp and I-bar clasp in the depth of undercut 0.5mm, 0.25mm, respectively, varying the length of clasp arm, that is, 10mm, 14mm, 17mm in Akers clasp and 16mm, 18mm, 20mm in I-bar clasp. The retentive force was measured just before the placement of removal, after 100 times repeated placement or removal, after 300 times repeated placement or removal. The obtained results were as follows : 1. The shorter the clasp arm, the greater retention in Akers clasp and I-bar clasp(p<0.05). 2. There was decreased retentive force of Akers clasp and I-bar clasp after 300 times repeated placement or removal(p.<0.005). 3. The decreasing rate of retentive force in Akers clasp with 10mm was higher than that with 17mm, after 300 times repeated placement or removal, but there was no statistica difference(p>0.05).
Keywords