Korean Journal of Air-Conditioning and Refrigeration Engineering (설비공학논문집)
- Volume 3 Issue 5
- /
- Pages.337-349
- /
- 1991
- /
- 1229-6422(pISSN)
- /
- 2465-7611(eISSN)
Prediction of Heat Transfer Rates to Spray Water Droplets in a High Pressure Mixture Composed of Saturated Steam and Noncondensable Hydrogen Gas
고압의 포화수증기-비응축성 수소기체 혼합기 속에서 분무수적으로의 열전달을 예측
Abstract
Heat and mass transfer rates to spray water droplets for spray transients in a high pressure vessel have been predicted by two different droplet models: the complete mixing model and the non-mixing model. In this process, the ambient fluid surrounding the droplets is a real-gas mixture composed of saturated steam and noncondensable hydrogen gas at high pressure. The physical properties of the mixture are estimated by applying the concept of compressibility factor and using appropriate correlations. A computer program, DROPHMT, to calculate the heat and mass transfer rates for two different droplet models has been developed. As an illustrative application of the computer program to engineering practices, heat and mass transfer rates to spray water droplets for spray transients in a Pressurized Water Reactor (PWR) pressurizer have been calculated, and the typical results have been provided.