Nuclear Engineering and Technology
- Volume 23 Issue 3
- /
- Pages.299-305
- /
- 1991
- /
- 1738-5733(pISSN)
- /
- 2234-358X(eISSN)
Theoretical Analysis and Effect of Condenser In-leakage in the Secondary Systems of YGN-1, 2
영광-1, 2호기 2차계통 복수기누설의 이론적 분석 및 영향평가
- Suk, Tae-Won (Korea Institute of Nuclear Safety) ;
- Lee, Yong-Woo (Korea Institute of Nuclear Safety) ;
- Kim, Hong-Tae (Korea Institute of Nuclear Safety) ;
- Park, Sang-Hoon (Korea Institute of Nuclear Safety)
- Published : 1991.09.01
Abstract
Corrosive environment may be generated within steam generators from condenser cooling water in-leakage. Theoretical analysis of the accumulation of chloride as a sea water impurity is being carried out for the condenser cooling water used at YGN-1,2 nuclear power stations. Calculations have shown that highly concentrated chloride solution would be produced within the steam generators in the case of sea water in-leakage. Maximum allowable design condenser leak rate(0.5 gpm) leads chloride concentration of 2.3 ppm at steam generetor and 0.6 ppm at hotwell with the maximum blowdown rate and condensate purification. Concentration factor at steam generator is dependent only on both blowdoum rate and condensate purification efficiency as follows, Concentration Factor(equation omitted)(B
복수기를 통한 해수유입은 증기발생기내에 부식환경을 조성시키게 한다. 이론적 분석을 통하여 복수기누설시에 해수증의 불순물인 염소가 2차계통내에 누적되는 경향을 영광원전을 모델로하여 평가하였다. 분석결과 해수누설시에 고농도의 염소가 증기발생기내에 누적되는 것으로 나타났으나, 이는 증기 발생기내의 수질을 산성분위 기로 조성시킬 것으로 판단되었다. 복수기의 최대허용 설계누설(0.5 gpm)시에는 증기발생기 취출수량을 최대로 늘리고, 복수기정화계통을 가동하더라도 증기발생기에 2.3 ppm 및 복수기집수정에 0.6 ppm의 염소가 누적되는 것으로 나타났다. 또한 증기발생기에서의 염소농축계수는 아래와 같이 전적으로 취출수량 및 정화계통효율에만 의존하는 것으로 나타났으며,(equation omitted)취출수 및 정화계통은 2차계통내의 불순물을 제거하는데 효과적인 것으로 평가되었다.
Keywords