Development of a Voltage Measuring System for the Pusan-Hamada Submarine Cable

부산 - 병전간 해저케이블 전압측정 장치의 개발

  • Bahk, Kyung-Soo (Ocean Environmental Engineering Laboratory, Korea Ocean Research and Development Institute)
  • Published : 1991.12.01

Abstract

A voltage measuring system specified for the voltage fluctuation of the Pusan-Hamada submarine cable is developed by adding circuits of differential amplification and analog-to-digital conversion to a microprocessor-based data logger with a data modem. This system is charaterized by its small size. no power failure. fully unmanned operation. and precise instrumental drift correction. In addition to the cable voltage and current it measures an ambient temperature and a mercury cell voltage in order to calibrate temperature effect and check its long-term stability. The data acquired by this system show that the voltage signal. comprising fast random noises with a constant width of about 0.2V. fluctuates within a range of about 1V and the fluctuation frequency is similar to that of tidal motion. The source voltage of power feeding equipment (PFE) for the cable system seems to be affected when the room temperature changes rapidly.

차동증폭과 A/D(analog-to-digital) 변환 회로를 마이크로프로세서(microprocessor)로 작동되는 데이타로거(data logger)에 연결하여 부산-하마다간의 해저케이블 전압변동을 기록하는 장치를 개발하였다. 이 장치는 저가격, 소형, 저전력소모가 특징이며 계기의 전압드리프트(drift)가 정밀수정되고, 무인자동으로 다량의 자료저장과 모뎀(modem)에 의한 자료전달이 가능하다. 케이블 전압 및 전류 이외에 실내온도와 수은전지 전압을 측정하는데, 이는 온도영향에 따른 오차보정과 장기관 계기안정도를 확인하기 위한 것이다. 이 계기에 의한 관측자료에 의하면 부산해저중계국에서의 전압신호는, 약 0.2 볼트의 일정한 폭의 높은 주파수의 잡음대로 이루어져 있는데, 조석과 비슷한 느린 주기로 약 1볼트 범위내에서 변동한다. 또한, 케이블 전원공급장치는 실내온도가 빠르게 변할 때 많은 영향을 받는 것으로 나타났다.

Keywords