Bandwidth Limitations of the TEM Cell due to Higher Order Modes

고차 모드로 인한 TEM Cell의 대역 제한

  • Published : 1991.11.01

Abstract

In this paper the electric and magnetic field distributions in a TEM cell used for EMC testing are analyzed numerically. The fields are distorted with the increase of frequency. These distortions are due to higher order modes and resonances and cause the bandwidthe limitations in the uae of TEM cels. The upper frequency is lower modes however, are reflected at some points through the tapered ends of the cell. Higher order modes however, are reflected at some points within the tapered region where it becomes too small to support the modes, The first two TE mode(TE$_{01}$ and TE$_{10}$) cutoff frequencies and the first six TE$_mnp$ resonant ferquencies are identified in a TEM cell (1x0 6x2m,w=0.72m) from field patterns and the results are consistent with others' data. The circumferential wall currents to support resonances are shown. For the large cell it is desired to extend the usable frequency range above the cutoff frequency of the first higher order mode. This study proposes an attempt to expand the frequency bandwidth by a resonance suppression.

Keywords