Protein-silica Interaction in Silica-based Gel Filtration Chromatography
Silica-based Gel Filtration 크로마토그래피에서의 단백질-실리카 상호작용
- Choi, Jung-Kap (College of Pharmacy, Chonnam National University) ;
- Yoo, Gyurng-Soo (College of Pharmacy, Chonnam National University)
- Published : 1991.12.28
Abstract
Silica-based gel filtration chromatography has been used to characterize molecular weight of proteins. However, the molecular weight measured by this method was distorted by protein-silica interactions like hydrophobic and electrostatic forces. Therefore, we characterized protein-silica interaction using two forms of phytochrome (124 kDa) having different hydrophobicity and surface charge. PH and ionic strength affected the retention time of phytochrome suggesting that electrostatic force is the major interaction between protein and silica surface.