Comparison of Dose Assessment Programs; DOSE, LIMCAL and PABLM

방사선 피폭선량프로그램 DOS, LIMCAL 및 PABLM의 비교

  • Published : 1991.06.30

Abstract

A comparison study is performed on dose assessment programs including DOSE, LIMCAL, and PABLM, DOSE is a program developed for preliminary safety assessments of the low- and intermediate- level radioactive waste disposal, and the others are existing programs applicable to similar calculations. The results show acceptable agreement within an order of magnitude(mrem/yr) except for C-14 and Pu-239. PABLM results higher dose for C-14 while lower value for Pu-239 in comparison with those from DOSE or LIMCAL. It is found that the discrepancy in C-14 is due to difference in transport model introduced and that in Pu-239 is from the different value of dose conversion factor to each program.

DOSE, LIMCAL 그리고 PABLM을 포함한 방사선피폭선량프로그램에 대하여 비교 연구가 행하여졌다. DOSE 프로그램은 국내 중 저준위 방사선폐기물 처분 예비안전성평가를 위해 확립되었으며, 나머지 두 프로그램은 안전성 평가에 적용한 바 있는 프로그램들이다. 연구 결과는 C-14과 Pu-239를 제외하고 1승(mrem/yr)범위에서 잘 일치하고 있다. PABLM은 DOSE와 LIMCAL과 비교할 때 Pu-239의 경우에서 작게 나타나고 있는 반면에 C-l4의 경우에는 크게 나타나고 있다. C-14의 편차는 소개된 이동모델에서의 차이 때문이며 Pu-239의 차이는 두 프로그램과 다른 선량전환인자 값을 적용함으로써 발생한 것임을 알 수 있다.