A Study on the Level of Air Pollution and Noise in Pusan Area

부산의 지역별 대기오염과 소음정도에 관한 조사연구

  • Cho, G.I. (Department of Preventive Medicine Inje Medical College Institute of Industrial Medicine, Paik Hospital) ;
  • Moon, D.H. (Department of Preventive Medicine Inje Medical College Institute of Industrial Medicine, Paik Hospital) ;
  • Lee, J.T. (Department of Preventive Medicine Inje Medical College Institute of Industrial Medicine, Paik Hospital) ;
  • Sin, H.R. (Department of Preventive Medicine Inje Medical College Institute of Industrial Medicine, Paik Hospital) ;
  • Kim, Y.W. (Department of Preventive Medicine Inje Medical College Institute of Industrial Medicine, Paik Hospital) ;
  • Park, H.J. (Department of Preventive Medicine Inje Medical College Institute of Industrial Medicine, Paik Hospital) ;
  • Pae, K.T. (Department of Preventive Medicine Inje Medical College Institute of Industrial Medicine, Paik Hospital) ;
  • Lee, C.U. (Department of Preventive Medicine Inje Medical College Institute of Industrial Medicine, Paik Hospital)
  • 조규일 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 문덕환 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 이종태 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 신해림 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 김용완 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 박형종 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 배기택 (인제대학교 의과대학 예방의학교실 및 산업의학연구소) ;
  • 이채언 (인제대학교 의과대학 예방의학교실 및 산업의학연구소)
  • Published : 1990.12.01

Abstract

In order to assess the degree of atmospheric pollution and noise and to contribute the health improvement of residents in Pusan, the author measured the levels of CO, $SO_2,\;NO_2$, TSP, HCHO and noise in 8 areas (industrial, residential and park areas) from January to March in 1990. The results were as follows : 1. Sasang industrial area was significantly higher($2.85{\pm}0.84ppm$) in the average concentration of CO than other areas. However, there no areas to affect the human body in terms of CO concentration. 2. In general, industrial area was significantly higher ($0.134{\pm}0.084ppm$) in the average concentration of $SO_2$ than other areas, and it was the lowest ($0.009{\pm}0.005ppm$) in the Namchon-dong area. 3. Industrial ($0.033{\pm}0.009ppm$) and residential area ($0.029{\pm}0.004ppm$) were significantly higher in the average concentration of $NO_2$ than Park area ($0.009{\pm}0.001ppm$). However, there were no areas to affect the human body in terms of $NO_2$ concentration. 4. Sasang industrial area was the highest ($580.4{\pm}415.26{\mu}g/m^3$) at the average concentration of TSP and Hae-Un Dae area was the lowest ($97.22{\pm}37.86{\mu}g/m^3$). But TSP concentration showed the level to affect the human body in most areas. 5. Industrial area was significantly higher ($2.25{\pm}1.15ppb$) in the average concentration of HCHO than residential ($1.13{\pm}0.25ppb$) and park area ($1.33{\pm}0.20ppb$). 6. Industrial area was significantly higher ($77.28{\pm}6.92dB(A)$) in the level of noise than residential ($65.77{\pm}3.76dB(A)$) and park area ($64.65{\pm}5.25dB(A)$). In comparison with regional Standard Noise Level, howeverm the average noise level of residential and park area was higher than that of the Standard. In general, the level of pollution of industrial complex areas was relatively higher than those of residential and park areas. Among the industrial areas, sasang area was worst in most items. Both $SO_2$ and TSP showed the level to affect the human body in most of studied areas. It is necessary to install a new Air Quality Standard for HCHO to screen our environmental pollution.