Left Ventricular Function Changes Under Normothermic Krebs Perfusate in Newborn Piglet
신생 돼지심장에서 상온의 Krebs 용액 관류에 따른 좌심실 기능의 변화
- O, Bong-Seok (College of Medicine, Chonnam University) ;
- Na, Guk-Ju ;
- Lee, Dong-Jun
- Published : 1990.12.01
Abstract
To clarify the changes of left ventricular function under normothermia, the time interval between the onset of ischemia and the beginning of contracture of left ventricle[TIC] were recorded in newborn piglet. Myocardial performance was assessed using intraventricular balloon to determine compliance and systolic function after 5 to 10 minutes interval per-fusing normothermic substrate free Krebs solution as a perfusate. The time to onset TIC was 29.5\ulcorner1.7 minutes and peak ischemic contracture was 46.7\ulcorner4.0 minutes[p<0.01]. In myocardial performance, systolic function of left ventricle[defined as cardiac contractility] was kept until 25 minutes of perfusion, but was decreased abruptly after 30 minutes of perfusion[p<0.0018] and diastolic function of left ventricle[defined as diastolic compliance] was kept until 15 minutes of perfusion, but was decreased after 20 minutes of perfusion [p=0.00\ulcorner9]. This study demonstrated maximal time of the tolerance to normothermic global ischemia and functional changes of left ventricle using Krebs perfusate under the same condition.