The Transactions of the Korean Institute of Electrical Engineers (대한전기학회논문지)
- Volume 39 Issue 12
- /
- Pages.1269-1280
- /
- 1990
- /
- 0254-4172(pISSN)
A Study on the Development of Drum-Type Boiler Simulator for Thermal Power Plant Using the Signal Flow Diagram Model
신호흐름도 모델을 이용한 화력 발전소 드럼형 보일러 시뮬레이터의 개발에 관한 연구
- ;
- ;
- ;
- Zeungnam Bien
- Published : 1990.12.01
Abstract
Owing to the need to accommodate the load variation, thermal power plants need a modern controller in order to achieve better frequency regulation, faster response and higher efficiency. For a successful development of the digital instrumentation and control system that can adopt advanced control algorithms, power plant simulator must be available for safe and convenient test. In this paper, a simple drum-type boiler model is proposed using Signal Flow Diagram that describes the system by a combination of basic time responses representing the relationships between cause and effect process variables. After verifying the model and thereafter building a simulator based on the proposed model, we tested the operation of the controller and stability or efficiency of the implemented control algorithms.
Keywords