초록
This study is concerned with the accuracy, of error with which subjects can interpolate the location of a target between two graduation markers with 4 orientations and 6 sizes CRT display. Stimuli were graphic images on CRT with a linear, end-markec, ungraduated scales having a target. The location of a target is estimated in units over te range 1-99. Smallest error of estimates was at the near ends and middle of the base-line. The median error was less than 2 units, modal error was 1, and the most error (; 99.7%) was within 10. A proper size to make an minimum error in interpolation exists such that size 400 pixels. Interpolation estimation is shown to be affected by the size, location and interaction (orientation x location, size x location). The accuracy, interpolation performance are discussed in relation to absolute error associated with visual performance.