Relationship between Oxygen Uptake and Cardiac Output on Maximal Treadmill Exercise in Marathoners by Improved Impedance Cardiography

Treadmill 최대 운동시 Impedance 심장기록법의 개선에 의한 마라톤 선수의 심박출량과 산소소비량과의 관계

  • Kang, Doo-Hee (Department of Physiology, Yonsei University College of Medicine) ;
  • Hwang, Soo-Kwan (Department of Physiology, Yonsei University College of Medicine) ;
  • Yeon, Dong-Soo (Department of Physiology, Yonsei University College of Medicine) ;
  • Yuh, Seon-Hee (Department of Physiology, Yonsei University College of Medicine) ;
  • Kim, Deok-Won (Department of Medical Engineering, Yonsei University College of Medicine)
  • 강두희 (연세대학교 의과대학 생리학교실) ;
  • 황수관 (연세대학교 의과대학 생리학교실) ;
  • 연동수 (연세대학교 의과대학 생리학교실) ;
  • 유선희 (연세대학교 의과대학 생리학교실) ;
  • 김덕원 (연세대학교 의과대학 의용공학과)
  • Published : 1990.12.30

Abstract

Maximal cardiac output and oxygen uptake $(VO_{2max})$ were measured during treadmill exercise for seven top-class marathoners and nine non-athletes using impedance cardiograph developed by one of the authors (DW Kim). Results of this study are summarized as belows. 1) New shoes with sponge and silicon rubber attached to the soles were developed to reduce motion artifact during treadmill exercise. Ensemble everaging techneque with the developed shoes was also used to improve the measurement of stroke volume using impedance cardiography. 2) Maximal cardiac output of the athletes, 14.98 L/min, was significantly higher than that of the non-athletes, 13.46 L/min. As maximal heart rate of the marathoners is lower than that of non-athletes, stroke volume of the former is significantly larger than that of the latter. 3) $VO_{2max}$ of the marathoners, 59.38 ml/kg/min, was higher than that of the non-athletes, 40.22 ml/kg/min. At the anaerobic threshold. $VO_{2max}$ of the former was 62.3% of $VO_{2max}$ and this was significantly higher than that of the non-athletes, 57.2%, This results indicates that the marathoners have higher aerobic capacity than the non-athletes. 4) The marathoners showed larger $VO_2$ than the non-athletes at the same cardiac output, indicating that a-v $O_2$ of the former is higher than that of the latter. 5) Maximal systolic pressure of the marathoners was higher than that of the non-athletes, and so was maximal rate-pressure products. These results indicate that heart oxygen consumption rate $(hVO_2)$ of the marathoner is higher than that of the non-athletes is mainly due to higher stroke volume. And higher oxygen consumption of the marathoners is due to higher stroke volume. And higher oxygen consumption of the marathoners is due to their larger a-v $O_2$. The marathoners show both higher threshold and $VO_{2max}$. Especially, measurement of cardiac output during treadmill exercise by improved impedance cardiography is expected to contribute in study of cardiac function of athletes.

Keywords