A Study on Physiochemical Analysis and Distributions of Coliforms in Major Streams or the Mankyung River

만경강 주요 지천수의 이화학적 검사 및 대장균군의 분포에 관한 연구

  • 황인담 (전북대학교 의과대학 예방의학교실) ;
  • 기노석 (전북대학교 의과대학 예방의학교실) ;
  • 정인호 (전북대학교 의과대학 예방의학교실) ;
  • 최문철 (전북대학교 의과대학 예방의학교실) ;
  • 이재형 (전북대학교 의과대학 예방의학교실)
  • Published : 1989.10.01

Abstract

This study was performed to investigate present water quality and pollution characteristics of them in the basin area of the Mankyung river near Chonju urban stream. In order to obtain the pollution characteristics of this investigation, the physio-chemical water analysis as temperature, pH, DO, BOD, Cd, Cu, Pb and Zn, and coliform group and their correlation analysis were determined from March to August 1988. The main results were summarized as follows 1. Each chemical constituent detected in three streams has the following variation range as pH(6.7-7.3), DO(1.3-8.9 mg/l), BOD(1.6-162.5mg/l) and water temperature was dominated by atmospheric temperature. 2. In three streams, concentration range of heavy metal was Cd N.D.-2.8 $\mu$g/l, Cu 1.1-10.2 $\mu$g/l, Pb 2.1-13.2 $\mu$g/l and Zn 25.6-62.2 $\mu$g/l, and was shown the order of Zn, Pb, Cu and Cd. 3. In the investigation on the bacteriological pollution-in the three streams. 1) The average number of general bacteria contaminated in the Chonju urban stream was $1.7 \times 10^{5}$ numbers/ml, which was higher than $2.6 \times 10^{2}$ numbers/ml, in the Gosan stream and 1.6 $\times$ 10 numbers/ml in the Mankyung river. 2) The average number of total coliform, fecal coliform and fecal streptococcus contaminated in the Chonju urban stream which was the highest polluted site than those of the other sampling sites were respectively $2.1 \times 10^{5}$, $2.1 \times 10^{5}$ and $9.6 \times 10^{4}$ MPN/100ml. 4. Correlation coefficient between GB and TC in the Chonju stream, Gosan stream and Mankyung river was respectively 0.99, 0.96 and 0.99, Correlation coefficient between TC and FC in Chonju stream, Gosan stream and Mankyung river was respectively 0.99, 0.97 and 0.99 and correlation coefficient between FC and TC was respectively 0.99, 0.91 and 0.99. This results mean positively dose relationship between them. 5. The occupied percentage of FC of TC in the Chonju stream, Gosan stream and Mankyung river was respectively 88.1%, 68.4% and 77.9% and the percentage of Tc of TS was respectively 43.5%, 31.6% and 41.4%. These .results was considered indicative of pollution derived from domestic wastes which had been contaminated by the feces of inhabitants and domestic animals.

Keywords