초록
Most of significant defects in the pressure boundaries of nuclear power plant we re dispositioned to be monitored periodically every inservice inspection. Due to the difficulty of the defect sizing during operation, it is necessary to develope the continuous flaw monitoring techniques. The Tip Diffraction method, specifically speaking, spot seems to be suitable for flaw monitoring. The optimum conditions of selecting the transducer were 3.5 MHz and 45-57 degree according to compatibility with the defect height. The effective calculation of the defect height was to assume the fact that the incident beam is parallel. This method would be supplemented to ASME method about the defect characterization for the surface flaw.