Derivation of Subcompartment Heat Transfer Correlation from HDR Tests

HDR 실험에 근거한 격납용기 구분방내의 열전달 상관식 도출

  • Published : 1987.06.01

Abstract

Statistical evaluation for the heat transfer correlation in the containment subcompartments is carried out from HDR experimental data. Heat transfer data for three HDR blowdown tests, V.42, V.43 and V.44, are analyzed to deduce the correlation. As Uchida already proposed, air-to-steam density ratio is proven to be the most affecting parameter in this study. Here Uchida heat transfer correlation is revised by including temperature difference between the atmosphere and the wall surface, and atmospheric pressure. In addition to these dependencies, atmospheric turbulence and time factor may be included in the model. This implication, however, is not successful, because turbulence and transient phenomena were not adequately quantified in the HDR program. It is concluded that a strong correlation exists between the heat transfer coefficient and temperature differences, specially for forced circulation conditions.

격납용기 구분방 내에서 정화한 열전달 상관식을 얻기 위해 HDR 실험 자료들을 통계적 인 방법으로 분석하였다. 세가지의 blowdown 시험, 즉 V.42, V.43 and V.44를 통해 얻어진 열전달 자료들이 상관식을 유도하는데 사용되었다. 이미 Uchida에 의해 제안되었던 air-to-steam 질량비는 이 실험에서도 역시 가장 중요한 인자로 입증되었다. 이 연구에서는 Uchida의 열전달 상관식으로 만족되지 않은 실험자료들을, 격납용기 대기와 벽 표면의 온도차의 함수로, 또 대기 압력의 함수로 표시하여 수정하려고 시도하였다. 이 종속성외에도 대기의 난류도와 시간에 따른 인자가 고려되어야 한다. 그러나 HDR 계획에서는 흐름속도의 측정 자료가 부정확하기 때문에 정량적인 관계식의 유도는 힘들다. 다만 열전달 계수와 온도 차이의 관계가 밀접하다는 사실을 밝혔으며 특히 강제순환 조건에서 더욱 이 관계는 명백해짐을 볼 수 있다.