A Study on Irradiation Effect by $Co^{60}$ of the R-C Series-Parallel Circuits

방사선조사에 의한 R-C 직.병렬회로에서의 손상효과에 관한 연구

  • Published : 1987.12.01

Abstract

The characteristis of all the instruments and materials used in atomic industry are changed due to irradiation damages by the effects of radiation activities. In this study when R-C series-parallel circuits are irradiated by $\gamma$-ray, variations in its electrical properties have been investigated. The following results are obtained. 1) In the R-C series circuit, the impedance variation ratio is increased as the irradiation quantity is increased up to $10^6[r]$, and above $10^6[r]$, the impedance variation ratio reached at the saturated condition. In the saturated condition, the increasing value was about 1.25 (%). 2) In the R-C series circuit, the power factor variation ratio is decreased as the irradiation quantity is in creased up to $10^6[r]$, and above $10^6[r]$, the power factor variation ratio reached at the saturated condition. In the saturated condition, the decreasing value was about 0.5(%). 3) In the R-C parallel circuit, the impedance variation ratio is increased as the irradiation quentity is increased up to $10^6[r]$, and above $10^6[r]$, the impedance variation reached at the saturated condition. In the saturated condition, the increasing value was about 0.5.(%). 4) In the R-C parallel circuit, the power factor variation ratio is decreased as the irradiation quantity is increased up to $10^6$[r], and above $10^6$[r], the power factor variation ratio reached at the saturated condition. In the saturated condition, the decreasing value was about 1.3(%).

원자력 산업에서 사용되고 있는 모든 재료의 특성은 방사선조사에 의한 손상효과로 변하게 된다. 본 연구에서는 저항과 콘덴서의 직.병렬회로에서의 방사선조사에 의한 전기적 특성이 여하히 변화되는가를 연구하였다. 연구결과 얻어진 주요 결론은 다음과 같다. 1. R-C 직렬회로에서 조사선량이 $10^6[r]$까지는 임피던스변화율이 증가되다가 그 이상의 조사선량에서는 포화상태에 이르게 되는데 포화상태에서의 증가율은 1.25[%]정도이었다. 2. R-C 직렬회로에서 조사선량이 $10^6[r]$ 까지는 증가변화율이 감소되다가 그 이상의 조사선량에서는 포화상태에 이르게 되는데 감소율은 0.5[%]정도이었다. 3. R-C 병렬회로에서는 방사선량이 $10^6[r]$까지는 임피던스변화율이 증가되다가 그 이상의 방사선량에서는 포화상태에 이르게 되는데 증가율은 0.5[%]정도이었다. 4. R-C 병렬회로에서는 방사선량이 $10^6[r]$까지는 감소되다가 그 이상의 방사선량에서는 포화상태에 이르게 되는데 감소율은 1.3[%]정도이었다.

Keywords