식각된 비귀금속합금과 법랑질을 복합레진계 시멘트로 접착시킨 경우의 접착인장강도에 관한 연구

A STUDY ON THE TENSILE BOND STRENGTH OF ETCHED-METAL RESIN-BONDED RETAINERS

  • 박헌석 (서울대학교 치과대학 보철학교실) ;
  • 이선형 (서울대학교 치과대학 보철학교실) ;
  • 양재호 (서울대학교 치과대학 보철학교실) ;
  • 장완식 (서울대학교 치과대학 보철학교실)
  • Park, Heon-Seok (Department of Prosthodontics, College of Dentistry, Seoul National University) ;
  • Lee, Sun-Hyung (Department of Prosthodontics, College of Dentistry, Seoul National University) ;
  • Yang, Jae-Ho (Department of Prosthodontics, College of Dentistry, Seoul National University) ;
  • Chang, Wan-Shik (Department of Prosthodontics, College of Dentistry, Seoul National University)
  • 발행 : 1986.12.01

초록

The purpose of this study was to compare the tensile bond strength of Comspan and Panavia as a luting materials between electrochemically etched Ni-Cr-Be alloy castings and acid etchea human tooth enamel. Tensile bond strength was evaluated using an Instron testing machine at a crosshead speed of 2mm/min. The following conclusions can be drawn frfm this study ; 1. The tensile bond strength of etched-metal resin-bonded specimen was $179.0{\pm}42.5kg/cm^2$ in case of Comspan and $169.6{\pm}41.4kg/cm^2$ in case of Panavia. 2. The tensile bond strength was not significantly different between Comspan, using with bonding agent, and Panavia, using without bonding agent.

키워드