Solar Energy (태양에너지)
- Volume 6 Issue 2
- /
- Pages.33-42
- /
- 1986
- /
- 0253-3103(pISSN)
A Study on the Measurement of Energy in a case of the Earth Bermed Housing
복토주택(覆土住宅)의 실례(實例)를 통한 에너지 측정(測定) 연구(硏究)
Abstract
The purpose of this paper is to research the performance of the energy in a case of the earth bermed House designed to be suitable for Korean situation in comparison with a conventional housing. The result of this study can be summerized as follows; 1) Heating energy of the earth bermed house is saved 40.1% than that of the conventional housing in Korea. 2) The time-lag of the earth bermed house is 57 minutes longer than that of a conventional housing on account of the thermal capacity, so the earth bermed house has much more satisfactory thermostatic mitigation effect rather than the conventional housing.