FITNESS OF THE COLLARLESS METAL-CERAMIC RESTORATIONS AT LABIAL MARGINS: A SCANNING ELECTRON MICROSCOPE STUDY

도재전장주조관의 순측 치경부 변연 적합도에 관한 주사전자현미경적 연구

  • Kim, Young-Han (Dept. of Prosthodontics, College of Dentistry Seoul National University) ;
  • Lee, Sun-Hyung (Dept. of Prosthodontics, College of Dentistry Seoul National University)
  • 김영한 (서울대학교 치과대학 보철학교실) ;
  • 이선형 (서울대학교 치과대학 보철학교실)
  • Published : 1985.12.01

Abstract

The purpose of this study was to evaluate the marginal fitness of collarless metal-ceramic crown formed with direct lift technique using wax compared with metal-ceramic crown with metal butt margin. Twenty crowns, ten were collarless metal-ceramic crowns and ten were metal-ceramic crowns with metal butt margins, were made and cemented on epoxy resin dies, and their marginal openings were measured on scanning electron microphotographic prints at x200 magnification. The results were as follows; 1. In the case of collarless metal-ceramic crowns, the mean marginal opeining was $43.78{\pm}17.67{\mu}m$, the mean maximum marginal opening was $52.81{\pm}19.81{\mu}m$, and the mean minimum marginal opening was $34.99{\pm}16.58{\mu}m$. 2. In the case of metal-ceramic crowns with metal butt margins, the mean marginal opening was $47.62{\pm}25.55{\mu}m$, the mean maximum marginal opening was $61.90{\pm}24.39{\mu}m$, and the mean minimum marginal opening was $34.86{\pm}24.92{\mu}m$. 3. There was no significant difference between two types of crowns at the 99% confidence level. 4. The marginal fitness of collarless metal-ceramic crown formed with direct lift technique using wax was clinically acceptable.

Keywords