A Study on the Magnetooptic Current Measurement System Using SF-4 Flint Glass

SF-4 Flint Glass를 이용한 자기광학적 전류측정시스템에 관한 연구

  • Published : 1985.05.01

Abstract

This paper describes fiber-optic current sensor using SF-4 flint glass for the first time, ails the flint glass has been theoretically analyzed by jones matrix and experimentally verified. Verdet constant of SF-4 flint glass, which determines the sensitivity of current sensor, has been experimentally found as 0.0606(min/g.cm). It is relatively lower value than currently used faraday rotators such as FR-5, SF-6 flint glasses and YIG. The fiber.optic current sensor system was established and the current measurement was performed in the range of 100-600 (A) and 100- 500 (G). It has beenfhown by the experi-mental results that the detector output linearly increased in proportion to the current. Since these experimental results were in good agreement with theoretical results, it has been shown that SF-4 flint glass can be used for the magnetooptic current sensor.

본 논문에서는 SF-4 flint glass를 이용한 fiber-optic 전류센서의 가능성을 처음으로 제시하였고 이를 실현하기 위하여 Jones matr항에 의한 이론적 분석과 실험을 하였다. 전류측정센서의 감도를 결정하는 SF-4 flint glass의 verdet 상수는 측정결과 0.0606[min/G·㎝]로 현재 연구 보고된 전류센서용 파라데이 회전자인 FR-5, SF-6 flint glass 및 YIC보다 비교적 작은 간으로 나타났다. 그리고 이론모델을 토대로 전류측정 시스템을 구성하여 100∼600(A)의 상용전류 및 100∼500(C)의 자계를 변화 시킴에 따라 검출기 출력을 측정한 결과 선형적으로 나타났다. 이는 이론적 결과와도 일치함 이 분석 되므로써 본 논문에서는 SF-4 flint 멍ass가 전류센서로서의 응용 가능성을 제시 하였다.