초록
By using the hollow shaft with $0.5^{\circ}$ internal taper, ball valve and rubber packing, charging the working fluid at engineering vacuum degree (vacuum pressure higher than 1 torr) and carrying out experiments, it was investigated the performance of rotating heat pipe with variant operating conditions. In this experiment, it was shown that it is impossible the internal liquid flow was laminar film flow which agree with the assumption of present theoretical analyses, but the internal vorticity makes the heat transfer increase and for the maximum heat transfer there is optimal mass loading for the given heat pipe geometry and operational conditions.