The Prediction of Void Fraction in the Subcooled Boiling Region

서브쿨드 비등 영역에서의 기포계수 계산에 관한 연구

  • Published : 1984.12.01

Abstract

A state-of-the-art mechanistic model has been developed to accurately predict the void fraction in the subcooled boiling region having axial nonuniform heat flux. In this study, the void-dependent drift-flux parameters of the Lahey/Ohkawa model were introduced and the mass flux-dependent condensation coefficient were determined by fitting with the experimental data. This model was tested against several experimental data sets to verify its accuracy. Finally the comparison between the predicted void fraction profiles with this model and the profile-fit model for the hot assembly of Kori-Unit 1, Cycle 1 has been performed. It is conclusive that the results show the good agreement between the measured and predicted void fractions, and the profile-fit model has been found to underestimate the void fraction in the subcooled boiling region.

축방향 비균일 열유량을 가지는 서브쿨드 비등영역에서 첨단적인 mechanistic 모델을 사용하여 기포계수를 정확히 계산하고저 한다. 이 모델에서는 Lahey/Ohama model에서 구한 기포계수에 의존하는 drift-flux계수를 사용하였고 또한 실제 실험치와 비교하여 질량유량에 의존하는 응축계수의 상관식을 구하여 사용하였다. 이 모델은 고 정확도를 증명하기 위해 잘 알려진 실험치들과 비교되었고 최종적으로 고리 1호기 1주기의 고온 연료집합체 기포계수를 계산하므로서 profilefit 모델과 비교되었다. 이러한 계산결과는 실험치와 잘 일치하고 있으며 profile-fit model은 서브쿨드 비등영역에서 기포 계수를 낮게 계산하고 있음이 밝혀졌다.

Keywords