Surgical correction in annuloaortic ectasia associated with ascending aortic aneurysm: one case report

거대상행핵대동맥루를 동반한 대동맥륜확장증 수술 치험: Cabrol씨 수술 1례 보

  • Published : 1984.12.01

Abstract

Most patients having annuloaortic ectasia are associated with marked dilatation of the sinuses of Valsalva and the aortic annulus as well as the huge aneurysm of the ascending aorta. A 19 year old male patient complaining of tightness on left posterior chest wall underwent cardiac angiography in which demonstrated annuloaortic ectasia with ascending aortic aneurysm and aortic insufficiency. The patient had corrective operation replacing the ascending aorta and aortic valve with a composite graft[Dacron prosthesis containing a Bjork-Shiley aortic valve] within the aneurysmal sac. The coronary orifices were anastomosed to the tubular Dacron prosthesis [30 mm in diameter] by means of a second smaller Gore-Tex tube [8mm in diameter]. The aneurysmal sac was trimmed by removing the redundant wall and then wrapped outer wall of the Dacron prosthesis. Postoperatively, mediastinal bleeding was temporarily observed in the operative day and satisfactory blood pressure was maintained with small dose of dopamine. One week later, large amount of serous effusion was drained out of the retrosternal space making partial disruption of the skin which was healed well by daily local dressing. The patient discharged in good condition on postoperative 29th day with no residual complications and is doing very well on the 4 months follow-up.

Keywords