The korean journal of orthodontics (대한치과교정학회지)
- Volume 14 Issue 2
- /
- Pages.241-248
- /
- 1984
- /
- 2234-7518(pISSN)
- /
- 2005-372X(eISSN)
THE STUDY 0F TENS10N CHARACTERISTICS IN ORTHODONTIC WIRES
교정용 철사의 인장 특성에 관한 연구
- Park, Dae-Han (Department of Orthodontics, College of Dentistry, Yonsei University) ;
- Ryu, Young-Kyu (Department of Orthodontics, College of Dentistry, Yonsei University)
- Published : 1984.09.01
Abstract
The mechanical properties of Cr-Ni alloy of austenitic stainless steel and Co-Cr alloy orthodontic wires were studied in tension. The wires (0.018 inch) were tested in the as-manufactured and heat-treated conditions. Instron type tension testing machine was used for this study. Mean values and standard deviations were computed. The results were as follows; 1. The Cr-Ni orthodontic wires of austenitic stainless steel are generally superior than the Co-Cr orthodontic wires in ultimate tensile strength, In the elongation, however, Co-Cr orthodontic wire are superior than Cr-Ni orthodontic wires. 2. Increase in the degree of strength by heat treatment are more clearly shown in Co-Cr orthodontic wires than Cr-Ni orthodontic wires. And the elongation is decreased by heat treatment in both case. 3. The changes of the degree of strength by cooling method we not clearly shown, but in Cr-Ni orthodontic wires, air cooling are more effective, in Co-Cr orthodontic wires, cooling effect are scarcely shown.