DNBR Sensitivities to Variations in PWR Operating Parameters

가압경수로의 운전변수 변화에 대한 DNBR의 민감도

  • Hyun Koon Kim (Korea Advanced Energy Research Institute) ;
  • Ki In Han (Korea Advanced Energy Research Institute)
  • Published : 1983.12.01

Abstract

Analyzed are the the DNBR(Departure from Nucleate Boiling Ratio) sensitivities to variations in various PWR operating parameters utilizing the Korea Nuclear Unit 1(KNU-1) design and operating data. Studied parameters in the analysis are core power level, system pressure, core inlet flow rate, core inlet temperature, enthalpy rise hot channel factor, and axial power peaking factor and axial offset. The calculations are performed using the steady state and transient thermal-hydraulics computer program, COBRA-IV-K, which is the revised version of COBRA-IV-i that has been adapted, partially modified and verified at KAERI. A reference case is established based on the design and operating condition of the KNU-1 reactor core, and this provides a basis for the subsequent sensitivity analysis. From the calculation results it is concluded that the most sensitive parameter in the DNBR thermal design is the coolant core inlet temperature while the axial power peaking factor is the least sensitive.

한국원자력 1호기(KNU-1)의 설계 및 운전자료를 이용하여 가압경수로 운전변수들의 변화에 대한 DNBR의 민감도를 분석하였다. 본 민감도 분석에는 원자로 출력, 압력, 냉각수 주입유량, 냉각수 주입온도, 반경방향 및 축방향 출력분포 그리고 축방향 출력편차 등의 운전변수가 고려되었다. 민감도 분석을 위하여는 노심의 열수력 해석용 전산코드인 COBRA-IV-K를 사용하였는데 본 코드는 COBRA-IV-i의 수정판으로써 한국에너지연구소에서 일부 프로그램을 수정하였고 또한 신뢰도도 확인하였다. 민감도 분석을 수행하기 전에 KNU-1 원자로심의 설계 및 운전조건을 근거로 하여 기초 계산을 수행하고 이 결과를 본 민감도 분석의 기본자료로 삼았다. 민감도 분석결과 원자로의 DNBR 열설계에 있어서 가장 민감한 운전변수는 냉각수 주입온도이고 가장 둔감한 변수는 축방향 출력분포라는 것이 밝혀졌다.

Keywords