Mechanisms, Experimental Results, Empirical Correlations and Analytic Models of Beat Transfer in Containment Building Following a LOCA

냉각재 상실 사고시 격납 용기내에 있어서의 열전달에 관한 기구, 실험결과, 선험 관계식 및 해석적 모형들에 관한 고찰

  • Published : 1983.06.01

Abstract

Estimates of the rate of heat removal from the containment atmosphere following a loss of colant accident (LOCA) are important to the prediction of containment peak pressure and temperature which are essential parameters in designing the containment building. An overall survey and discussion of mechanisms, experimental results, empirical correlations and analytical models that are relevant to the heat transfer inside the containment have been made. As a result of this review, the current state of the knowledge about tile containment heat transfer can be understood and it is known that more investigations are needed to avoid the misuse of various correlations.

냉각재 상실 사고시에 격납 용기로부터 열 제거능력의 추정은 격납용기의 기본적인 설계변수인 최고 압력 및 온도의 예측에 있어서 매우 중요하다. 지금까지 격납 용기내의 열전달에 관하여 실험 및 해석적인 방법에 의하여 연구한 결과들을 종합하여 검토해 봄으로서 현재의 수준을 알 수 있었으며, 이들 관계시의 잘못된 사용을 피하고 보다 정확한 예측을 위해서는 더욱 깊은 연구가 필요하다고 생각된다.

Keywords