Reflood Experiments with Horizontal and Vertical Flow Channels

  • Published : 1980.09.01

Abstract

The investigation of the fuel cladding temperature behavior and heat transfer mechanism during the reflooding phase of a LOCA plays an important role in performance evaluation of ECCS and safety analysis of water reactors. Reflooding experiments were performed with horizontal and vertical flow channels to investigate the effect of coolant flow channel orientation on rewetting process. Emphasis was mainly placed on the CANDU reactor which has horizontal pressure tubes in core, and the results were compared with those of vertical channel. Also to investigate the rewetting process visually, the experiments by using a rod in annulus and a quartz tube heated outside were performed. It can be concluded that the rewetting velocity in horizontal flow channel is clearly affected by flow stratification, however, the average rewetting velocity is similar to those in vertical flow channel for same conditions.

냉각재상실사고의 재관수 단계중 연료봉 피복재의 온도거동 및 열전달 기구를 파악하는 것은 비상노심냉각계통 및 원자로의 안전성해석에 중요하다. 냉각재유동채널의 방위가 rewetting과정에 미치는 영향을 연구하기 위하여 수직 및 수경 유동채널을 이용한 실험을 수행하였으며, 노심이 수평압력관으로 구성되어 있는 CANDU원자로에 관한 실험을 중점적으로 수행하여 그 결과를 수직채널의 결과와 비교 하였다. 또한 rewetting현상을 육안관찰가기 위해 환상형 테스트부 및 외부에서 가열되는 석영관을 사용하였다. 실험결과로써 수평채널에서의 rewetting 속도는 유동의 층상 현상에 크게 영향을 받으나 그 평균값은 수직채널리 경우와 큰차이없음을 알 수 있었다.

Keywords