Analytic Design of a Ferroresonant Transformer for Microwave Heating System

초고주파 가열장치에 사용하는 철공진 변압기의 해석적 설계

  • 나정웅 (한국과학원 전기 및 전자공학과) ;
  • 김원수 (경북대공대 전자공학과)
  • Published : 1979.01.01

Abstract

In the microwave heating system, a ferroresonant transformer is used to regulate the magnetron power fluctuation. For the simplification, nonlinear characteristics of the transformer and the magnetron are idealized to be piecewise linear. Dipped peak shape of the magnetron current is explained qualitatively by considering the fundamental and third harmonic frequency components in the circuit. Design equations providing the values of the leakage inductance, turn ratio of the transformer and the capacitance are derived analytically by cosnidering the fundamental frequency component only. The ferroresonant transformer is designed to obtain a required regulation and high input power factor from the derived design equations, and analytical calculations are compared with experimental measurements.

Keywords