Double Valve Replacement: A Report of 23 Cases

중복판막이식: 23 치험예

  • Published : 1978.12.01

Abstract

Between January 1974 and November 1978, 23 cases of double valve replacement were done in the Department of Thoracic Surgery, Seoul National university Hospital. All had symptoms of rheumatic valvular heart disease and belonged to functional class III or IV according to NYHA classification. Among 23 cases, mitral and aortic valves were replaced in 14, and mitral and tricuspid valves in 9 cases. Six operative deaths [26%] and 4 late deaths [23%] were found. In the former group 5 and in latter one operative death were noted. Main cause of operative death was low cardiac output syndrome due to myocardial failure. Among 4 late deaths, 2 were caused by thromboembolism, one by bacterial endocarditis, and one by arrhythmia.