Potentiometric Determination of Copper with 2,5-Dimercapto-1,3,4-thiadiazole

2,5-Dimercapto-1,3,4-thiadiazole에 의한 구리의 전위차 적정 정량

  • Young Gu Ha (Department of Chemistry, College of Natural Sciences, Seoul National University)
  • 하영구 (서울대학교 자연과학대학 화학과)
  • Published : 1976.08.30

Abstract

A potentiometric titration method has been developed for the titration of copper with 2,5-dimercapo-1,3,4-thiadizole in aqueous solution using a silver electrode as an indicator electrode vs. the standard calomel electrode as a reference electrode. The 2,5-dimercapto-1,3,4-thiadiazole is very sensitive reagent for copper, which has been found to be highly selective for potentiometric determination of copper. Direct titration of trace amount of copper (0.02${\sim}$0.1 mg) is possible in the presence of a number of foreign ions in aqueous solution containing potassium hydrogen phthalate and sodium fluoride as masking agent under atmosphere.

은 전극을 지시전극으로 하고 표준칼로멜 전극을 기준전극으로 하여 전압플로위회로를 이용하여 수용액에서 2,5-dimercapto-1,3,4-thiadiazole에 의한 구리의 전위차 적정법을 연구하였다. 이 시약은 구리의 전위차 적정 정량에 뛰어나게 이용할 수 있었고 여러가지 가리움제를 사용하여 다른 이온들의 존재하에 대기중에서 미량의 구리를 직접 적정할 수 있었다.

Keywords

References

  1. J. Korean Chem. Soc. v.17 Young Gu Ha;Q. Won Choi
  2. Anal. Chem. v.28 V. W. Meloche;L. Kalbus
  3. Anal. Chem. v.32 B. Miller;D. N. Hume
  4. Anal. Chem. Acta. v.20 A. K. Majumdar;M. M. Chakrabartty
  5. Anal. Chem. v.34 W. Stricks;S. K. Chakravarti
  6. Atti. Accad. Nazl. Lincei Rend. Classe Sci. Fis. Mat. Nat. v.8 A. Liberti;E. Cervone
  7. Anal. Chem. v.60 Q. Won Choi