Measurement of the fast Neutron Flux Density in the Bulk Shielding Experimental Tank of the TRIGA Mark-II Reactor Using Solid State Track Detector

  • Published : 1973.12.01

Abstract

The horizontal distribution of the fast neutron flux density in the Bulk Shielding Experimental Tank of the TRIGA Mark-II reactor at the steady power of 250 KW has been measured using a solid state track detector which is natural mica placed in contact with $^{232}$ Th fissile foil. The neutron flux density was calculated on the assumption that the fast neutron spectrum is similar to that from the thermal-induced $^{235}$ U fission. The resulting flux density distribution along the horizontal line from the center of the thermalizing column door is presented in tabular and graphical forms.

$^{232}$ Th 핵분열 물질과 조합된 고체비적검출체를 사용하여 250kw로 정상운전되는 TRIGA Mark-II 원자로의 대차폐수조내에서 열중성자주(thermalizing column)의 중심으로부터 수평방향의 속 중성자 선속밀도 분포를 추정하였다. 속 중성자 스펙트럼이 $^{235}$ U가 열 중성자에 의하여 핵분열이 일어날매 방출되는 중성자 스펙트럼과 같다는 가정을 한 다음, 선속밀도는 고쳬비적검출체로 얻어진 실험 결과로부터 계산되었다. 이와 같은 방법으로 속 중성자 설속밀도 분포의 측정 결과는 도표로서 제시된다.