Prediction of Human Body Volume from Height and Weight

신장과 체중을 이용한 남자의 신체 용적 간접 측정

  • Kim, Key-Yong (Department of Physiology and Physical Culture Research Institute, Seoul National University College of Medicine)
  • 김기용 (서울대학교 의과대학 생리학교실 및 국민체력과학 연구소)
  • Published : 1970.06.01

Abstract

Human body volumes were calculated from the measurments of body height and body weight. Equations Suited to express the relations of height, weight, and surface area to show the body volume were derived from the body volume measurements by means of underwater. weighing method. Underwater body weights were corrected for the residual volume of long obtained by the Rahn's three breath method. Underwater weighing was performed on 173 male subjects aged between 13 and 51 years. Subjects were divided into 4 age groups, namely, 13-16 years group of 47 subjects, 16-19 years group of 46 subjects, adult group aged between 22 and 38 years comprising 45 subjects, and middle-aged group (40-51 years) of 35 subjects. The group division was made on .the basis of physical growth and development. The following results were obtained. 1. Body height (H, cm), body weight (W, kg), body surface area $S,\; m^{2})$, and body volume (V, liter.) interrelated closely. V/S showed a high correlation with W/H and the coefficient of correlation was r=0.97 irrespective of age group differences of the subjects. The coefficients of correlation between V/S and W/H in the total mate subjects as a single group was r=1.983. Subsequently the following regression equation was obtained. V = S X (54.84 W/H + 14.08) The agreement of body volume values obtained by the calculation and underwater weighing in the total subject group was better than that of the separate age group division. 2. The calculated values of body volume were: 40.4 l (euiqvalent to the body density value of 1.0562 kg/1) in 13-16 years group; 52.0 l (equivalent to density value of 1.0723 kg/l) in 16-19 years group; 55.3 l (equivalent to density value of 1.0570 kg/l) In the adult group; and 54. 0 l (equivalent to density value of 1.074 kg/l) in the middle-age group. The mean deviation of calculated from the measured volume value ranged between ${\pm}0.55$ and ${\pm}0.81$ liters. 3. The correlation between V/S and mean skinfold thickness of 4 sites (arm, back, iliac and chest) was high, namely, the coefficient of correlation was r=0.656. The coefficients of correlation between V./S and the $R\"{o}hrer$ index ranged between r=0.668 and r=0.810 affected by the difference in group age of the subject. The body volume (V) alone correlated poorly than V/S with mean skinfold thickness (r=0.606) and the $R\"{o}hrer$ index (r ranged between 0.274 and 0.588).

Keywords