Flame Retardant Performance of Functional Oil Stains According to the Mixing Ratio of Inorganic Flame Retardants and Phosphorus Flame Retardants

무기계 방염제와 인계 방염제 혼합비율에 따른 기능성 오일스테인의 방염성능

  • 이주원 (한밭대학교 건설환경조경대학 건축공학과) ;
  • 이상수 (한밭대학교 건설환경조경대학 건축공학과)
  • Published : 2023.11.10

Abstract

Wood is a construction material that has the advantages of carbon dioxide storage ability, noise reflection, and eco-friendliness. In order to use wood for a long time, you must use wood-specific paint, which is called oil stain. Oil stain improves water resistance and moisture resistance, but has the disadvantage of being weak against fire. This is because the oil contained in the oil stain causes a chemical reaction, and this chemical reaction causes the oil stain to spontaneously ignite, igniting nearby combustible materials and causing frequent fires. To improve this, in this study, different flame retardants were mixed and added to oil stain to produce functional oil stain. In addition, we would like to apply it to wood to check glow time and carbonization area. As a result of the experiment, it shows the best performance when mixed at 30(15 + 15)(%) and added to oil stain. The remaining burn time is satisfied from 10% for all samples, and the carbonized area is satisfied when it is 30%.

Keywords

References

  1. 김두배. 균등 마이크로파를 적용한 방수, 방염처리 첨단 내장목재 개발을 위한 기초적 연구. 동명대학교 대학원. 2008.
  2. 김황진. 방염도료의 방염성능에 관한 연구. 호서대학교 대학원. 2008.