화재시뮬레이션을 이용한 터널 내 화재시 제연설비 필요성 검토

A Study on the necessity of smoke control system in the tunnel fire using fire simulation

  • 발행 : 2022.04.20

초록

In this study, fire simualtion was performed to examine the necessity of smoke control system in the tunnel fire. The heat release rate was set to 5 MW and 20MW, and the visibility was measured at 1.8 m, which is the breathing limit, when there is no jet fan. Through this, it was confirmed that 5 MW did not affect the visibility even without the jet fan, and in the case of 20 MW, a jet fan was required to secure the visibility. The visibility was measured at the same location by installing the jet fan, and the simulation was performed by reducing the design volume flow rate of 8.5 m3/s by 80% and 50%, respectively. As a result, it was confirmed that sufficient visibility was secured when the design flow rate and 80% were reduced.

키워드

과제정보

이 연구는 2021년도 소방청 및 과학기술정보통신부가 출연하는 국민소방협력 초기대응 현장지원 기술개발사업의 재원으로 한국산업기술평가관리원의 지원을 받아 수행되었음(과제번호: 2016433).