Energy Performance Evaluation Study on the Thermal Bridge Blocking External Insulation System for Green Remodeling

그린 리모델링용 열교 차단 외단열 시스템의 에너지 성능 평가 연구

  • 김웅회 (주식회사 스타빌엔지니어링) ;
  • 강은호 (한밭대학교 건축공학과) ;
  • 윤종호 (한밭대학교 건축공학과)
  • Published : 2021.11.12

Abstract

We set the representative balcony types of the existed building to two types: unexpanded balcony and extended balcony, and analyze the effect of reducing the cooling and heating energy load when applying remodeling. The scope of the study was limited to balcony walls, including window-wall junctions, and was conducted by comparing cases with and without thermal break insulation structures for a clear conclusion. The study was conducted using the equivalent U-value in each case. The equivalent U-value was calculated by deriving through 2 dimensional steady-state heat transfer analysis of each case balcony envelope. And building energy was calculated using the derived equivalent U-value. According to the calculation results, for unexpanded balconies, the equivalent U-value was reduced by about 80%, and the heating and cooling load was reduced by about 20%. In the case of extended balconies, the equivalent U-value was reduced by about 57% and the resulting heating and cooling load was reduced by about 12%.

Keywords