Proceedings of the KIPE Conference (전력전자학회:학술대회논문집)
- 2020.08a
- /
- Pages.160-162
- /
- 2020
Soft-Switching Auxiliary Current Control for Improving Load Transient Response of Buck Converter
- Kim, Doogwook (School of Energy Systems Engineering, Chung-Ang University) ;
- Shin, Joonho (School of Energy Systems Engineering, Chung-Ang University) ;
- Shin, Jong-Won (School of Energy Systems Engineering, Chung-Ang University)
- Published : 2020.08.18
Abstract
A control technique for the auxiliary buck/boost converter is proposed herein to improve the load transient response of the buck converter. The proposed technique improves the system efficiency by enabling the soft switching operation of the auxiliary converter. The design guidelines for achieving capacitor charge balance for the output capacitor during the transient are also presented herein. The experimental results revealed that the output voltage undershoot and settling time during the load step-up transient were 40 mV and 14 ㎲, respectively, and the output voltage overshoot and settling time during the load step-down transient were 35 mV and 21 ㎲, respectively. The performance and effectiveness of the proposed technique were experimentally verified using a prototype buck converter with a 15-V input, 3.3-V output, and 200-kHz switching frequency.