Setting Time Prediction of Super Retarding Concrete Using Improved Durometer

개량형 듀로미터를 이용한 초지연 콘크리트의 응결시간 분석

  • 한수환 (청주대학교 건축공학과) ;
  • 최윤호 (청주대학교 건축공학과) ;
  • 연규원 ((주) JW 구조기술사사무소) ;
  • 김종 (청주대학교 건축공학과) ;
  • 한민철 (청주대학교 건축공학과) ;
  • 한천구 (청주대학교 건축공학과)
  • Published : 2020.06.12

Abstract

In this study, the feasibility of the durometer into super retarding concrete was studied by comparing the penetration resistance with the hardness of each durometer using the penetration resistance and the improved Durometer and Durometer A-Type according to the ultra-delay mixture rate. The test results showed that initial setting time by improved Durometer and Durometer A-Type were fixed at 25, 50 HD, respectively, and the 35, 80 HD showed at final setting time. It was also found that the use of the durometer can be available to measure the setting time of the concrete.

Keywords