In this paper is presented a pre-charging sequence for single-phase cascaded neutal-point-clamped(NPC) converters for capacitors voltage balancing. capacitor imbalance problem in pre-charge sequence is caused in cascaded NPC converter by its topology. the DC link voltage at each NPC converter module can be balanced by the proposed switching method. the design and performance of the proposed sequence are verified by simulation and experimental results using prototype.