In this study, fundamental properties by pore structure and heat of microhydration test were determined. As a result of pore structure analysis, BS(AA) specimen showed showed the maximum peak value of significantly lower incremental intrusion than the maximum peak value of incremental intrusion at smaller pore size than that of BS. As a result of heat of microhydration test, the maximum heating value was in the order of OPC > BS > BS(AA), and initial drying shrinkage and compressive strength of BS(AA) were expected to be improved.