원전구조물의 Gr.80 전단철근 사용을 위한 ASME-CC 코드개정에 관한 연구

ASME-CC Code Change to use the Gr.80 Shear Reinforcement in Nuclear Power Plant Structure

  • 발행 : 2015.05.28

초록

Generally significant reinforcement is used in nuclear power plant structures and may cause potential problems when concrete is poured. In particular pouring concrete into structural member joint area is more difficult than other areas since the joint area is very congested due to the crossed bars and the embedded plates, The purpose of this study is to solve these problems by applying Gr.80(550MPa) shear bars to containment structures of nuclear power plant. In order to apply them to containment structures, it is necessary to change ASME-CC code (ASME Sec.III Div.2). The structural performance tests of wall & beam have been done to compare Gr.80(550Mpa) with Gr.60(420MPa) shear bars. The test results and code change proposal were presented to ASME-CC Committee last year and the discussion for code change will be expected to proceed in the near future.

키워드