CFD 해석을 이용한 Multi Inner Stage Cyclone 내부의 미세입자제거 효율 예측 및 실험적 검증

Efficiency Prediction of the Particle Removal Efficiency of Multi Inner Stage(MIS) Cyclone by Computational Fluid Dynamics(CFD) Analysis and Experimental Verification

  • 김혜민 (평택대학교 환경에너지기술융합연구센터) ;
  • 권성안 (평택대학교 환경에너지기술융합연구센터) ;
  • 이상준 (평택대학교 환경에너지기술융합연구센터)
  • Kim, Hye-Min (Environment & Energy Convergence Tech. R&D, Pyeongtaek University) ;
  • Kwon, Sung-An (Environment & Energy Convergence Tech. R&D, Pyeongtaek University) ;
  • Lee, Sang-Jun (Environment & Energy Convergence Tech. R&D, Pyeongtaek University)
  • 발행 : 2012.07.11

초록

A new multi inner stage(MIS) cyclone was designed to remove the acidic gas and minute particles of harmful materials produced from electronic industry. To characterize gas flow in MIS cyclone, pressure and velocity distribution were calculated by means of computational fluid dynamics(CFD) commercial program. Also, the flow locus of particles and particle removal efficiency were analyzed by Lagrangian method. When outlet pressure condition was -1,000 Pa, the efficiency was the best in this study. Based on the CFD simulation result, the pressure loss and destruction removal efficiency was measured through MIS cyclone experiment.