수배전반 진단을 위한 통합형 센서모듈

An Integrated Sensor Module for Diagnosis of Closed Switchboards

  • 차상욱 (한국해양대학교, 전기전자공학부) ;
  • 차현규 (한국해양대학교, 전기전자공학부) ;
  • 박대원 (한국해양대학교, 전기전자공학부) ;
  • 박희철 (부산교통공사, 운영본부 차량검수팀) ;
  • 길경석 (한국해양대학교, 전기전자공학부)
  • 발행 : 2011.10.20

초록

According to the statistical report from National Emergency Management Agency (NEMA) in Korea, the accident rate of closed switchboards in power systems occupies over 40%. In this paper, an integrated sensor module for monitoring the condition of closed switchboards is described. The sensor module monitors electro-magnetic (EM) wave, ultra-violet (UV) ray, heat and smoke generated by electrical discharges or insulation breakdown. The effective detection ranges were decided from experiment results; 100 kHz~10 MHz for EM wave, 220 nm~395 nm for UV ray and 0~$150^{\circ}C$ for heat, respectively. The prototype sensor module includes all functions above-mentioned in one device.

키워드