Case Study on Mega Foundations of Domestic and Foreign Super High-Rise Buildings

국내외 초고층 건축물의 대단면 매트기초 시공사례와 분석

  • 박영석 (연세대학교 건축공학과) ;
  • 이해출 ((주)선진엔지니어링 종합건축사사무소) ;
  • 김경민 (연세대학교 건축공학과) ;
  • 조창식 (연세대학교 건축공학과) ;
  • 임홍철 (연세대학교 건축공학과)
  • Published : 2010.05.14

Abstract

This paper describes the possibility of the raft thickness reduction for mega foundations system of super high-rise buildings through a case study on domestic and foreign super high-rise buildings. In case of super high-rise buildings, the size of foundations, especially raft becomes wider and deeper because of heavy upper load. It is difficult to pour concrete of this kind of mega foundation, and cracks by hydration heat could happen. Therefore, there are several ways to reduce the raft thickness of mega foundations. Piled-raft could be the one because moment and shear load that the raft subjects on by soil reaction are lower. The effect of the piled-raft foundation on the raft thickness reduction could be confirmed by comparison of super high-rise buildings with pile, piled-raft and mat foundation. Furthermore, it was showed that the raft thickness could be more reduced by locating piles right under the vertical members of super structures.

Keywords