한국전산유체공학회:학술대회논문집
- 2010.05a
- /
- Pages.501-504
- /
- 2010
SIMULATION STUDIES ON A REDUCED-SCALE SUBWAY COACH FIRE
지하철 축소모형 객차화재 수치해석적 연구
Abstract
In this study, fire behavior for subway coach fire in the 1/10 reduced scale model is analyzed using numerical analysis method (FDS). The size of the reduced model coach is 1.9 m long, 0.290 m high and 0.235 m. The simulation is carried out only one-sided four doors of the coach are opened. A fire source is the n-heptane pool fire with a mean heat release rate 2.33 kW. Smoke temperature, heat release rate and mass loss rate for the model are calculated.